Authorised Schneider Electric distributor for Africa

| Number of poles | Filter products by 2P |
|---|---|
| Tripping curve | Filter products by C |
Schneider ElectricEarth Leakage & Residual Current Devices
Order code
Select a variant in this series
Every option is a reference in this catalogue. A faded option changes more than one value — its nearest reference is linked.
List R1 431.73 Your price R973.58
Excluding VAT · per unit · volume pricing available on request
Listed in stock — availability is re-confirmed on every order
IC60H2 – earth leakage circuit breaker – 2P – C curve – 16 A – 30m A – 240 V — Schneider Electric order code A9D11216.
Download datasheet (opens in a new tab)
In this overview
A9D11216 — IC60H2 – earth leakage circuit breaker – 2P – C curve – 16 A – 30m A – 240 V by Schneider Electric. Listed under Earth Leakage & Residual Current Devices on the Schneider Electric catalogue at RMS-SE.Africa.
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P circuit breaker with 2 protected poles, In rated current of 16A and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-1 and IEC 61009-2-2 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 110mm x (D) 75.5mm. The weight is 332g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -15C to 60C. The storage temperature is from -40C to 85C.
number of poles 2P; tripping curve C.
A9D11216Prices in ZAR excluding VAT; stock and lead time are confirmed on every written quotation from RMS Measurement & Control, Johannesburg.
Data supplied by the manufacturer. Confirm against the official datasheet before ordering.
| Brand | Filter products by Schneider Electric |
|---|---|
| GTIN / EAN | Filter products by 3606480558733 |
| Range | Filter products by Acti 9 iC60 RCBO |
| Lifecycle status | Filter products by Current |
| ETIM class | Filter products by EC000905 |
| Number of poles | Filter products by 2P |
|---|---|
| Tripping curve | Filter products by C |
| Datasheet | Download datasheet |
|---|
| SKU/Code/Partnumber | Filter products by A9D11216 |
|---|
Published by the manufacturer for this part. Each one opens in a new tab.
Same series, same mounting and the same documentation set.
A9R41425Acti9 iID, RCCB, 4 pole, 25A, 30mA, type ACList R1 500.99 Your price R1 020.67View product
A9R61263Acti9 iID – RCCB – 2P – 63A – 30mA – type A-SIList R1 346.04 Your price R915.31View product
A9R12463Acti9 iID, RCCB, 4 pole, 63A, 100mA, type ACList R1 325.32 Your price R901.22View product
A9R61240Acti9 iID, RCCB, 2 pole, 40A, 30mA, type A-SIList R1 306.82 Your price R888.64View product
A9R41440Acti9 iID, RCCB, 4 pole, 40A, 30mA, type ACList R1 608.41 Your price R1 093.72View product
A9R61225Acti9 iID, RCCB, 2 pole, 25A, 30mA, type A-SIList R1 241.50 Your price R844.22View product
A9D32616Acti9 iDPN N Vigi – RCBO – 1P+N – 16A – C Curve – 6000A – 30mA – type AList R1 210.63 Your price R823.23View product
A9XMLA02Act9 – locking clips for Smartlink with Linergy FM 80AList R198.99 Your price R135.31View product
A9XMFA04Acti 9 – mounting kit for Smartlink on DIN railList R497.43 Your price R338.25View product
A9XM2B04Acti 9 – mounting kit for Smartlink with Linergy FM 200 AList R191.33 Your price R130.10View product
A9XCATM1USB-Modbus cable test Acti 9 SmartlinkList R2 487.15 Your price R1 691.26View product
A9R61463Acti9 iID, RCCB, 4 pole, 63A, 30mA, type A-SIList R2 153.66 Your price R1 464.49View product
A9R61440Acti9 iID, RCCB, 4 pole, 40A, 30mA, type A-SIList R1 972.58 Your price R1 341.35View product
A9R61425Acti9 iID, RCCB, 4 pole, 25A, 30mA, type A-SIList R1 840.82 Your price R1 251.76View product
A9R50240Acti9 iID K – residual current circuit breaker – 2P – 40A – 30mA – type ACList R904.74 Your price R615.22View productRMS supplies each manufacturer range from its own storefront. These links open a different RMS site in a new tab.
A9D11216 is the order code for IC60H2 – earth leakage circuit breaker – 2P – C curve – 16 A – 30m A – 240 V. It belongs to our Earth Leakage & Residual Current Devices range. RMS-SE.Africa supplies it as genuine Schneider Electric product, sourced through the manufacturer's distribution channel.
It is listed as in stock. Availability is re-confirmed on every order before any payment is taken, so what you order is what actually ships.
Use "Add to quote" and submit the quote basket. The RMS team prices every line, confirms stock, and emails you a formal quotation with written lead times — and you can accept it online to turn it into an order.
No. Checkout submits the order without payment; we confirm stock for every line first, then email you a secure payment link for the order.