Authorised Schneider Electric distributor for Africa

Products

All products

Brands

All brands

Explore

Categories Industries Guides Downloads Tools RMS Group Contact

Sign in

Close menu

Engineering & supplier tools

Find the part, then check it against the manufacturer.

Find parts and quote them in one place — by order code, by rating, or as a pasted parts list — then check anything against the manufacturers' own documentation and selection tools. Those are theirs, not ours, and are labelled as such.

Find parts and build your quote

Three ways in, one quote. Type an order code or the rating you need, filter the catalogue by its own values, or paste a whole parts list. Whatever you add lands in your quote request beside it, where you can check it, change it and send it without leaving this page.

Code or description

An order code, part of one, or the ratings you need: current, poles, voltage, coil, enclosure. Every answer is a part on this site, and where it differs from what you asked for, the difference is named.

Start from a category

Results are read from this catalogue and ranked by how closely they match. Written explanations are not enabled on this site.

What this searches

It matches only against the products published on this catalogue. A part RMS can supply but has not published here will not appear — send that one to us directly and we will source it.

These aids search and filter what is published on this catalogue. They do not see your installation — not the supply, the fault level, the ambient temperature, the cable, the duty or the standard you are designing to — and they make no allowance for any of it. Nothing they return is a design calculation, a compliance check, or a substitute for competent engineering design by a suitably qualified person. Check every result against the manufacturer's own documentation and the applicable standard before you order or build.

Filter by rating

What this filters on

Only on attribute values actually recorded against products on this catalogue. A product whose rated current has not been captured is excluded from a filter on rated current, so removing a filter can reveal more valid options, not fewer. It applies no derating, no coordination and no selectivity check.

These aids search and filter what is published on this catalogue. They do not see your installation — not the supply, the fault level, the ambient temperature, the cable, the duty or the standard you are designing to — and they make no allowance for any of it. Nothing they return is a design calculation, a compliance check, or a substitute for competent engineering design by a suitably qualified person. Check every result against the manufacturer's own documentation and the applicable standard before you order or build.

Paste a parts list

Paste a schedule straight out of a spreadsheet, or type the lines. Every line is matched against this catalogue, with price, stock and an alternative where needed, and anything that cannot be matched is carried into your request for the sales desk.

No part numbers to hand? Describe what you need instead.

How finding and quoting works on RMS-SE.Africa

  1. A code is matched exactly firstAn order code is looked up as written, then without the spaces and hyphens suppliers add. A single mistyped character is corrected only when exactly one part in the catalogue is that close; two candidates is a guess, and a guess on an order code ships the wrong part.
  2. A rating is matched against the parts' own dataCurrent, poles, voltage and the rest are compared with what is recorded against each product. A part that meets some of it but not all is shown as a possible match, with what differs named.
  3. A pasted list keeps every lineEach line is matched, and anything that cannot be is carried into the request as text for the sales desk to source. A suggestion is always labelled as a suggestion, never as a confirmed equivalent.
  4. The request is checked by a personPrices shown are list prices in rand excluding VAT. Every line is confirmed against stock and current pricing before a formal quotation is issued, and nothing is charged.

Questions about quoting

Can I quote a whole bill of materials at once?

Yes. Paste it as it comes out of a spreadsheet, one part per line: the order code and the quantity, separated by a tab, a comma, a space or an "x". Up to 250 lines go in at once. Signed in, every line is matched against the catalogue; otherwise the first 50 are, and the rest go to the sales desk as you wrote them.

What if a part is not on this site?

It goes into the request as text and the sales desk sources it, or call +27 11 708 2811. Nothing is offered in its place unless it is labelled as an alternative.

Do I need an account?

No. A name and an email address are enough for a quotation. Signed in, your quotations are also kept under Quotations in your account.

Compare ranges

The same duty across several ranges, at the ratings each manufacturer publishes — with this site's prices on its own order codes.

Calculation aids

Motor starter selector — contactor and overload by motor rating

Enter the motor rating on the nameplate. We list the order codes whose own published AC-3 rating covers it, on this site, with prices.

Searching 179 contactors on this site whose manufacturer states an AC-3 motor rating (up to 450 kW) and 70 overload relays with a printed setting range. Both nameplate figures are on the motor; we do not calculate one from the other.

Assumptions

Every rating shown is the manufacturer's own published figure for that order code — the AC-3 motor rating at 400 V for a contactor, and the printed setting range for an overload relay. Nothing on this page converts kW into amps: no power factor or efficiency is assumed, because the motor's full-load current is on its nameplate and that is the number an overload relay is set from. Direct-on-line starting of a standard cage induction motor is assumed for the AC-3 duty; star-delta, soft-start, plugging, inching and switched-capacitor duties change the selection and we will quote them.

These aids search and filter what is published on this catalogue. They do not see your installation — not the supply, the fault level, the ambient temperature, the cable, the duty or the standard you are designing to — and they make no allowance for any of it. Nothing they return is a design calculation, a compliance check, or a substitute for competent engineering design by a suitably qualified person. Check every result against the manufacturer's own documentation and the applicable standard before you order or build.

Manufacturer tools and documentation

These are the manufacturers' own tools, hosted on their own sites. RMS does not operate them and cannot change what they return. Every link below leaves this site and opens in a new tab.

Official manufacturer tools and document libraries
Tool Manufacturer Type What it does
ABB DriveSize Opens ABB DriveSize on abb.com, in a new tab ABB Selection tool Dimensions an ABB drive and motor against a load profile and reports the resulting selection.
ABB Library Opens ABB Library on library.abb.com, in a new tab ABB Document library Datasheets, catalogues, manuals, certificates and declarations for ABB products, searchable by product code.
ABB low-voltage product pages Opens ABB low-voltage product pages on abb.com, in a new tab ABB Manufacturer catalogue The manufacturer's own pages for the low-voltage range: ratings, ordering data and technical descriptions.
ElectroMechanica catalogues Opens ElectroMechanica catalogues on em.co.za, in a new tab ElectroMechanica Document library The published catalogues for the ElectroMechanica range, by product family.
ElectroMechanica certification Opens ElectroMechanica certification on em.co.za, in a new tab ElectroMechanica Compliance documents Certificates and compliance documentation published by ElectroMechanica for its range.
ElectroMechanica downloads Opens ElectroMechanica downloads on em.co.za, in a new tab ElectroMechanica Document library Datasheets, manuals and software downloads published by ElectroMechanica.