Authorised Schneider Electric distributor for Africa

| Rated current (Iu) | Filter products by 115 A |
|---|---|
| Rated voltage (Ue) | Filter products by 690 V |
| Number of poles | Filter products by 3P |
| Max Break Capacity | Filter products by 50 kA |
| Product Series | Filter products by TeSys GV4 |
Schneider ElectricMotor Protection Circuit Breakers
Order code
List R13 047.00 Your price R8 871.96
Per unit · volume pricing available on request
excl. VAT R10 202.75 incl.
Listed in stock — availability is re-confirmed on every order
In stock — 1–2 working days if stocked locally, 3–5 working days if sourced
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals — Schneider Electric order code GV4PE115N. Rated current 115 A; 3P; breaking capacity 50 kA; rated voltage 690 V.
In stock — 1–2 working days if stocked locally, 3–5 working days if sourced
View on the Schneider Electric site (opens in a new tab)
Select a variant in this series
Every option is a reference in this catalogue. A faded option changes more than one value — its nearest reference is linked.
In this overview
GV4PE115N — Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals by Schneider Electric. Listed under Motor Protection Circuit Breakers on the Schneider Electric catalogue at RMS-SE.Africa.
TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
Key specifications: rated current 115 A; 3P; breaking capacity 50 kA; rated voltage 690 V.
GV4PE115NTeSys GV4 is a Schneider Electric range with 52 references listed on RMS-SE.Africa, from 2 A to 115 A. It spans Motor Protection Circuit Breakers, Contactors.
GV4PE115N is rated 115 A.
GV4PE115N is a 3P device.
The catalogue states 50 kA for GV4PE115N. Check the datasheet for the value at your system voltage.
The manufacturer datasheet is linked under “Ordering information” above; the product page also carries the manufacturer’s documents where Schneider Electric publishes them.
Yes. GV4PE115N is supplied through the manufacturer’s authorised channel with the standard Schneider Electric warranty, and every order is confirmed against stock before payment.
Published by the manufacturer for this part. Each one opens in a new tab.
Data supplied by the manufacturer. Confirm against the official datasheet before ordering.
| Product Name | GV4PE115N – Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals Schneider Electric |
|---|---|
| Brand | Filter products by Schneider Electric |
| Product Series | Filter products by TeSys GV4 |
| GTIN / EAN | 3606481310309 |
| Lifecycle status | Filter products by Current |
| ETIM class | Filter products by EC000074 |
| Number of poles | Filter products by 3P |
|---|---|
| Rated current (Iu) | Filter products by 115 A |
| Rated voltage (Ue) | Filter products by 690 V |
| Operating Voltage | Filter products by 690V |
| Max Break Capacity | Filter products by 50 kA |
| Datasheet | View on the Schneider Electric site |
|---|
| Breaking capacity icu | Filter products by 50 kA at 400 V |
|---|---|
| Related Categories | Filter products by Plug – in Relays, Filter products by Timers & Control Relays, Filter products by Motor Protection Circuit Breakers |
| SKU/Code/Partnumber | Search products for GV4PE115N |
| Iternational GTIN | 3606481310309 |
| Mount Type | Filter products by Plug-in |
Same series, same mounting and the same documentation set.
GV4PEM50NMotor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic multifunction, Everlink terminalsList R20 189.28 Your price R13 728.71View product
GV4PEM50SMotor circuit breaker, TeSys GV4, 3P, 50A, Icu 100kA, thermal magnetic multifunction, Everlink terminalsList R22 024.66 Your price R14 976.77View product
GV4PEM80BMotor circuit breaker, TeSys GV4, 3P, 80A, Icu 25kA, thermal magnetic multifunction, Everlink terminalsList R18 389.01 Your price R12 504.53View product
GV4PEM80NMotor circuit breaker, TeSys GV4, 3P, 80A, Icu 50kA, thermal magnetic multifunction, Everlink terminalsList R20 208.61 Your price R13 741.85View product
GV4PEM03SMotor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink terminalsList R27 772.66 Your price R18 885.41View product
GV4PEM12SMotor circuit breaker, TeSys GV4, 3P, 12.5A, Icu 100kA, thermal magnetic multifunction, Everlink terminalsList R26 440.14 Your price R17 979.30View product
GV4PEM25NMotor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic multifunction, Everlink terminalsList R23 757.20 Your price R16 154.90View product
GV4PEM25SMotor circuit breaker, TeSys GV4, 3P, 25A, Icu 100kA, thermal magnetic multifunction, Everlink terminalsList R25 916.95 Your price R17 623.53View product
GV4PE50NMotor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, Everlink terminalsList R13 040.00 Your price R8 867.20View product
GV4PE80NMotor circuit breaker, TeSys GV4, 3P, 80A, Icu 50kA, thermal magnetic, Everlink terminalsList R13 040.00 Your price R8 867.20View product
GV6P320HMotor circuit breaker, TeSys GV6, 3P, 320A, Icu 70kA, thermal magneticList R13 286.00 Your price R9 034.48View product
GV4PE115BMotor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminalsList R11 861.00 Your price R8 065.48View product
GV4PE115SMotor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, Everlink terminalsList R14 233.00 Your price R9 678.44View product
GV4PE80BMotor circuit breaker, TeSys GV4, 3P, 80A, Icu 25kA, thermal magnetic, Everlink terminalsList R11 855.00 Your price R8 061.40View product
GV5P150HMotor circuit breaker, TeSys GV5, 3P, 150A, Icu 70kA, thermal magneticList R10 354.00 Your price R7 040.72View product
GV5P150FMotor circuit breaker, TeSys GV5, 3P, 150A, Icu 36kA, thermal magneticList R9 424.00 Your price R6 408.32View product
GVAPL01Laser plotting tool for rotary handle mounting, TeSys GV-UList R1 259.42 Your price R856.41View product
GVAPK12Shaft support bracket for deep enclosure, TeSys GV3, for depth exceeding 300 mmList R153.00 Your price R104.04View product
GVAPK11Shaft support bracket for deep enclosure, TeSys GV2, for depth exceeding 250 mmList R102.00 Your price R69.36View product
GV6P500HMotor circuit breaker, TeSys GV6, 3P, 500A, Icu 70kA, thermal magneticList R25 133.27 Your price R17 090.62View product
GV6P500FMotor circuit breaker, TeSys GV6, 3P, 500A, Icu 36kA, thermal magneticList R23 671.03 Your price R16 096.30View product
GV4PEM50BMotor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic multifunction, Everlink terminalsList R18 353.89 Your price R12 480.65View product
GV4PE25SMotor circuit breaker, TeSys GV4, 3P, 25A, Icu 100kA, thermal magnetic, Everlink terminalsList R24 655.51 Your price R16 765.75View product
GV4PE50BMotor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminalsList R17 236.73 Your price R11 720.98View productRMS supplies each manufacturer range from its own storefront. These links open a different RMS site in a new tab.
GV4PE115N is the order code for Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals. It belongs to our Motor Protection Circuit Breakers range. RMS-SE.Africa supplies it as genuine Schneider Electric product, sourced through the manufacturer's distribution channel.
Schneider Electric rates Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals at 115 A. It is a 3P-pole device.
Schneider Electric specifies a breaking capacity of 50 kA at 400 V.
Schneider Electric rates it for 690 V.
It is listed as in stock. Availability is re-confirmed on every order before any payment is taken, so what you order is what actually ships.
Use "Add to quote" and submit the quote basket. The RMS team prices every line, confirms stock, and emails you a formal quotation with written lead times — and you can accept it online to turn it into an order.
No. Checkout submits the order without payment; we confirm stock for every line first, then email you a secure payment link for the order.