Authorised Schneider Electric distributor for Africa

Products

All products

Brands

All brands

Explore

Categories Industries Guides Downloads Tools RMS Group Contact Sign in Close menu
Save 32%
Circuit breaker basic frame, Masterpact NT12H1, 42 kA at 440 VAC 50/60 Hz, 1250 A, drawout, without Micrologic, 3 poles
Key specifications
Number of polesFilter products by 3P

Schneider ElectricAir Circuit breakers (ACB's)

47230 – Circuit breaker basic frame, Masterpact NT12H1, 42 kA at 440 VAC 50/60 Hz, 1250 A, drawout, without Micrologic, 3 poles | Schneider Electric

Order code

Select a variant in this series

Poles

Every option is a reference in this catalogue. A faded option changes more than one value — its nearest reference is linked.

List price

List R62 150.68 Your price R42 262.46

Excluding VAT · per unit · volume pricing available on request

Listed in stock — availability is re-confirmed on every order

Circuit breaker basic frame, Masterpact NT12H1, 42 kA at 440 VAC 50/60 Hz, 1250 A, drawout, without Micrologic, 3 poles — Schneider Electric order code 47230.

Download datasheet (opens in a new tab)

Ordering & delivery
  • Contact us for bulk pricing, lead times and ordering codes.
  • Minimum order: 1 unit.
  • Manufacturer's standard warranty applies.
  • Collection from our branch, delivery in the Johannesburg area, and export across Africa on request.
  • Some items are held off-site rather than in our own warehouse — availability is confirmed on every order.
  • Authorised Schneider Electric distributor
  • Genuine product with manufacturer warranty
  • Formal quotations with written lead times

Overview

47230 — Circuit breaker basic frame, Masterpact NT12H1, 42 kA at 440 VAC 50/60 Hz, 1250 A, drawout, without Micrologic, 3 poles by Schneider Electric. Listed under Air Circuit Breakers (ACBs) on the Schneider Electric catalogue at RMS-SE.Africa.

About 47230

This is a basic frame for 3 poles Masterpact NT12H1 drawout circuit breaker. Masterpact NT is a comprehensive range of air circuit breakers designed to protect electrical systems from damage caused by overloads, short circuits and equipment ground faults. The breaking capacity (Icu) is 42kA rms at 440VAC 50/60Hz. The rated current is 1250A. This basic frame is compatible with any type of Micrologic control unit which has to be ordered separately. The basic frame must be associated with the corresponding chassis which has also to be ordered separately. With Micrologic control unit, Masterpact NT contributes to safety and energy efficiency. It can be equipped with a variety of optional functions and accessories. The dimensions are 288mm (W) x 322mm (H) x 277mm (D). It ensures compliance with international standards (IEC 60947), UL489, CCC, EAC and marine specifications.

47230 key specifications

breaking capacity 42 kA at 440 V AC; number of poles 3P; rated frequency 50 / 60 Hz.

Ordering information for 47230

  • Order code: 47230
  • Manufacturer: Schneider Electric
  • Range: Masterpact NT
  • GTIN / EAN: 3303430472308
  • ETIM class: EC000228
  • Datasheet: manufacturer datasheet for 47230

Prices in ZAR excluding VAT; stock and lead time are confirmed on every written quotation from RMS Measurement & Control, Johannesburg.

Technical specifications

Data supplied by the manufacturer. Confirm against the official datasheet before ordering.

Identification & ordering

BrandFilter products by Schneider Electric
GTIN / EANFilter products by 3303430472308
RangeFilter products by Masterpact NT
Lifecycle statusFilter products by Current
ETIM classFilter products by EC000228

Electrical ratings

Number of polesFilter products by 3P
Rated FrequencyFilter products by 50 / 60 Hz

Documents

DatasheetDownload datasheet

Other specifications

SKU/Code/PartnumberFilter products by 47230
Breaking capacity icuFilter products by 42 kA at 440 V AC

Documents

Published by the manufacturer for this part. Each one opens in a new tab.

More in the Masterpact NT range

2 items

Same series, same mounting and the same documentation set.

Similar items

8 items

More in Air Circuit breakers (ACB's)

8 items

Alternatives on our other RMS storefronts

RMS supplies each manufacturer range from its own storefront. These links open a different RMS site in a new tab.

Quick answers

What is 47230?

47230 is the order code for Circuit breaker basic frame, Masterpact NT12H1, 42 kA at 440 VAC 50/60 Hz, 1250 A, drawout, without Micrologic, 3 poles. It belongs to our Air Circuit breakers (ACB's) range. RMS-SE.Africa supplies it as genuine Schneider Electric product, sourced through the manufacturer's distribution channel.

Is it available?

It is listed as in stock. Availability is re-confirmed on every order before any payment is taken, so what you order is what actually ships.

How do I get a formal quotation?

Use "Add to quote" and submit the quote basket. The RMS team prices every line, confirms stock, and emails you a formal quotation with written lead times — and you can accept it online to turn it into an order.

Do I pay when I order?

No. Checkout submits the order without payment; we confirm stock for every line first, then email you a secure payment link for the order.